Troubleshooting

Quick Diagnosis

Symptom Likely Cause Fix
Plugin not in sidebar Not installed or browser cache Hard refresh (Cmd+Shift+R / Ctrl+Shift+F5)
"TrueNAS (tns-csi)" missing from sidebar Plugin not loaded Check Headlamp plugin manager or restart Headlamp pod
No StorageClasses listed Wrong provisioner or driver not installed See Driver Detection
Driver status "Not installed" CSIDriver object missing kubectl get csidriver tns.csi.io
Protocol/Pool/Server showing "—" StorageClass missing parameters kubectl get sc <name> -o yaml to inspect
403 on any page Missing RBAC See RBAC Issues
Metrics page empty Controller pod unreachable or no metrics See Metrics Issues
Snapshots tab: "CRD not available" Snapshot CRD not installed Install snapshot.storage.k8s.io CRDs
Snapshots tab empty (no message) No snapshots or wrong snapshot class Check VolumeSnapshotClass driver field
Benchmark fails immediately Missing RBAC for Jobs/PVCs See Benchmark Issues
Benchmark stuck in "Running" kbench pod not starting kubectl get pods -n <ns> -l app.kubernetes.io/managed-by=headlamp-tns-csi-plugin
Page loads but data is stale Watch connection dropped Click the Refresh button or reload the page

Driver Detection

The plugin detects the tns-csi driver by querying:

GET /apis/storage.k8s.io/v1/csidrivers/tns.csi.io

If this returns 404, the driver shows as "Not installed".

Check:

kubectl get csidriver tns.csi.io

If missing, verify the tns-csi driver is deployed. The driver registers its CSIDriver object on startup.

StorageClass Parameters Showing "—"

StorageClass Protocol, Pool, and Server come from the StorageClass parameters field.

Check:

kubectl get sc -o yaml | grep -A5 "provisioner: tns.csi.io"

Expected output includes:

parameters:
  protocol: nfs
  pool: tank/k8s
  server: 192.168.1.1

If parameters is absent, the StorageClass was created without them — the CSI driver documentation specifies the required parameters for each protocol.

Controller Pods Not Showing

The Overview page shows controller and node pod counts using label selectors:

  • Controller: app.kubernetes.io/name=tns-csi-driver,app.kubernetes.io/component=controller
  • Node: app.kubernetes.io/name=tns-csi-driver,app.kubernetes.io/component=node

Check:

kubectl get pods -n kube-system -l app.kubernetes.io/name=tns-csi-driver

If pods exist but aren't showing, verify the app.kubernetes.io/component label is set correctly.

Infinite Loading Spinner

If a page shows a loading spinner indefinitely:

  1. Check browser console for errors (F12 → Console)
  2. Check network tab for failed API requests (look for 403, 404, 500)
  3. Check Headlamp pod logs: kubectl logs -n <your-namespace> -l app.kubernetes.io/name=headlamp
  4. Try refreshing — the watch connection may have been interrupted

Common API Errors

HTTP Status Meaning Action
401 Unauthorized Token expired or invalid Re-authenticate in Headlamp
403 Forbidden Missing RBAC permission See RBAC Issues
404 Not Found Resource doesn't exist Expected for optional resources (CSIDriver, snapshot CRD)
503 Service Unavailable API server overloaded Wait and retry

Getting More Information

Browser console:

F12 → Console tab

Look for errors related to tns-csi, headlamp-plugin, or Kubernetes API paths.

Headlamp pod logs:

kubectl logs -n <your-namespace> -l app.kubernetes.io/name=headlamp --tail=100

tns-csi controller logs:

kubectl logs -n kube-system -l app.kubernetes.io/name=tns-csi-driver,app.kubernetes.io/component=controller --tail=100